archicorner
AC 063 - Egress Sample - 5 of 5: Fire Extinguishers & Egress Signs
6:40
archicorner
AC 062 - Egress Sample - 4 of 5: Exit Widths and Door Swings
9:07
archicorner
AC 061 - Egress Sample - 3 of 5: Paths of Travel
4:53
archicorner
AC 060 - Egress Sample - 2 of 5: Number of Exits and Distance Between Exits
5:20
archicorner
AC 059 - Egress Sample - 1 of 5: Occupant Loads
6:31
archicorner
AC 058 - Roof Venting
12:11
archicorner
AC 057 - Mezzanines - IBC requirements
15:06
archicorner
AC 053 – Permitting and Construction process
14:45
archicorner
AC SHORT 008 - When Are Fire Service Elevators Required?
0:59
archicorner
AC SHORT 007 - Stacked Buildings
0:59
archicorner
AC SHORT 006 - Occupancy Loads vs. Occupancy Groups
0:57
archicorner
AC 056 - Building Separation Requirements
15:02
archicorner
AC 055 - Accessible Shelving
14:17
archicorner
AC 054 - Occupant Area Vs Usable Area
8:26
archicorner
AC 052 - Reaction to finally getting my Architect's License
12:54
archicorner
AC 051 - How to coordinate with Plan Checkers
8:01
archicorner
AC 050 - How to calculate plumbing count
11:59
archicorner
AC 049 - Corridors Vs. Exit Passageways (with corrected audio)
5:30
archicorner
AC 049 - Corridors Vs. Exit Passageways
5:30
archicorner
AC 048 - Elevator Hoistway Protection
10:12
archicorner
AC 047 - Fire Extinguishers
13:32
archicorner
AC SHORT 005 - Distance to Exits
0:54
archicorner
AC 046 - Parking mania!
12:47
archicorner
AC SHORT 004 - Is it a Basement or Story Above Grade?
1:00
archicorner
AC SHORT 003 - Including Penthouses in Building Heights
0:58
archicorner
AC SHORT 002 - Measuring Building Heights on Sloped Grade Plane
1:00
archicorner
AC 044 - Fire & Smoke Dampers - What are they? And, where are they required?
10:01
archicorner
AC SHORT 001 - How To Measure Building Height
0:56
archicorner
AC 034 - Nonseparated Occupancies.
13:11
archicorner
AC 043 - Egress Example.
10:35
archicorner
AC 042 - Why and how to prepare for meetings!
10:09
archicorner
AC 041 - How to find fire rated wall designs.
11:51
archicorner
AC 040 - Shear Walls: What are they and how do they work?
14:32
archicorner
AC 039 - How to figure out the allowable area for multi-occupancy & multi-story buildings.
13:40
archicorner
AC 038 - How to figure out the allowable area for a single occupancy building.
21:06
archicorner
AC 035 - "Accessible Units", "Type A Units" & "Type B Units".
10:08
archicorner
AC 036d - What are "Shaft Walls" and why use them?
9:49
archicorner
AC 036c - Why use Slotted Top Tracks In metal framing
4:08
archicorner
AC 005 - UPDATED April 2022!!! - Typical ADA Requirements for ramps
8:09
archicorner
AC 036b - Why are studs spaced at 12", 16", and 24" ?
4:24
archicorner
AC 036a - Why Architects specify metal framing vs wood framing.
6:14
archicorner
AC 037 - Q&A Time!!!
14:09
archicorner
AC 033 - Accessory Occupancies - What are they?
11:26
archicorner
AC 032 - Occupancy Separations
5:50
archicorner
AC 031 - Horizontal exits explained. FINALLY!
22:06
archicorner
AC 030 - Occupant Load vs Occupancy Groups
5:51
archicorner
AC 029 - Number of Exits, Travel Distance & Common Path of Travel
9:23
archicorner
AC 028 – What are Dead End Corridors and how to avoid them?
6:49
archicorner
AC 027 - IBC requirements: What is the required distance between exit doors?
12:39
archicorner
AC 026 - USF & RSF vs Net & Gross S.F. and when to use each.
5:49
archicorner
AC 025 – USF vs RSF & What are the basic BOMA requirements for office buildings?
11:33
archicorner
AC 024 - Difference between: Girder, Beam, Joist, Rafter, Truss, Stud, Sill Plate & Top Plate.
10:40
archicorner
AC 023 - SPECIAL!!! Software used for Videos & Channel Update!
14:56
archicorner
AC 007 - UPDATED!!! - ADA Size and Clearance Requirements for Doors
6:29
archicorner
AC 022 - Egress: How to calculate occupant loads (Part 2 of 2) - Gross vs. Net. Sq. Ft.
9:43
archicorner
AC 021 - Stair ADA and IBC requirements
17:25
archicorner
AC 020 - The Best Video on Accessibility Requirements for Restrooms - CALIFORNIA EDITION!!!
25:02
archicorner
AC 019 - The Best Video on ADA Requirements For All Restroom Fixtures!!!
21:07
archicorner
AC 018 - Push Buttons & Automatic Door Openers.
8:59
archicorner
AC 017 - Egress: Where is Panic Hardware or Fire Exit Hardware Required by Code (IBC)?
5:34
archicorner
AC 016 - What is the difference between Construction Type I and Type II per the IBC?
5:21
archicorner
AC 015 - What is a fire rated wall?
2:58
archicorner
AC 014 - The Best IBC Chapter 10 Overview Ever! (In 10 minutes)
10:22
archicorner
AC 013 - Egress: How many exits are required from a space?
4:04
archicorner
AC 012 - ADA Requirements for Toilets: Water Closets
2:34
archicorner
AC 011 - Egress: How to Calculate Egress Widths.
6:52
archicorner
AC 010 - Egress: How to Calculate Occupancy Loads (Part 1 of 2) - The Basics
6:29
archicorner
AC 009 - ADA requirements for signage installation
4:33
archicorner
AC 008 - ADA requirements for signage
5:56
archicorner
AC 007 - Basic ADA requirements for Door Clearances
4:05
archicorner
AC 006 - ADA vs Bldg Code Accessibility
6:12
archicorner
AC 005 - Typical ADA Requirements fo ramps
4:42
archicorner
AC 004 - Building Types
6:08
archicorner
AC 003 - Occupancy Groups
7:03
archicorner
AC 002 - Residential project building permit process
4:09
archicorner
AC 001 - INTRO
0:44